GammaPRO® Wireless Gamma Detection System
Wireless gamma detection system aids in identifying target nodes quickly and confidently in a broad range of anatomy.
Inquire About this Product
The GammaPRO System includes innovative and clinically relevant technical features that help to solve the toughest challenges of radioguided surgical procedures. With its modern design, high sensitivity, best-in-class detection, exceptional spatial resolution, dynamic response time, and intuitive software it can easily help to fulfill the needs in every clinical application for open and laparoscopic surgeries. The system is battery operated with a battery life of 15+ hours. It offers a full range of entirely wireless with a reliable Bluetooth connection and completely sterilizable probes that help to identify sentinel lymph nodes in a large majority of patients. It can detect up to 9 isotopes and measure 3 simultaneously. The system can be easily transportable in its lightweight briefcase.
Smaller Incision. Greater Confidence.
With multiple probe options available, the GammaPRO system’s rapid response time and minimal lag aids in identifying target nodes quickly and confidently in a broad range of anatomy. The slim and precise titanium tip can help to minimize the size of an incision keeping the outcome for the patient top of mind.
The Laparoscopic Probe can be used for clinical applications with superficial drainage like breast, melanoma, parathyroid, head and neck. The Angled Probe can be used for clinical applications with superficial drainage like breast, melanoma, parathyroid, head and neck. It allows ease of detection, as well as enhanced access and visibility in confined anatomical spaces for advanced lymphatic mapping. The Hi-Sense Probe can be used for head and neck procedures, providing greater precision in identifying targeted parathyroid adenomas. The Standard Probe can be used for clinical applications with deep drainage like prostate, lung, cervix, or endometrium. It can fit through a trocar and is the ideal choice for minimally invasive surgical procedures.
Specifications
- 5230-0150 Standard Probe
- Total Length: 10″ (255 mm)
- Tip Diameter: 0.43″ (11 mm)
- Total Weight Including Battery: 0.35 lb (157 g)
- Spatial Resolution (FWHM) at 1 cm: ≤12 mm @ 140 keV (Tc-99)
- Maximum Sensitivity: ≥ 23 cps/kBq @ 140 keV (Tc-99) (850 cps/μCi)
- Sensitivity at 1 cm: ≥ 3.4 cps/kBq @ 140 keV (Tc-99) (125 cps/μCi)
- 5230-0151 Hi-Sense Probe
- Total Length: 10″ (255 mm)
- Tip Diameter: 0.61″ (15.5 mm)
- Total Weight Including Battery: 0.39 lb (177 g)
- Spatial Resolution (FWHM) at 1 cm: ≤20 mm (without col) ≤12 mm (with col)
- Maximum Sensitivity: ≥ 95 cps/kBq @ 140 keV (Tc-99) (3500 cps/μCi)
- Sensitivity at 1 cm: ≥ 18.9 cps/kBq @ 140 keV (Tc-99) (700 cps/μCi)
- 5230-0152 Laparoscopic Probe
- Total Length: 20″ (514 mm)
- Tip Diameter: 0.43″ (11 mm)
- Total Weight Including Battery: 0.39 lb (177 g)
- Spatial Resolution (FWHM) at 1 cm: ≤12 mm @ 140 keV (Tc-99)
- Maximum Sensitivity: ≥ 23 cps/kBq @ 140 keV (Tc-99) (850 cps/μCi)
- Sensitivity at 1 cm: ≥ 3.4 cps/kBq @ 140 keV (Tc-99) (125 cps/μCi)
- 5230-0153 Angled Probe
- Total Length: 10″ (259 mm)
- Tip Diameter: 0.43″ (11 mm)
- Total Weight Including Battery: 0.27 lb (122 g)
- Spatial Resolution (FWHM) at 1 cm: ≤6.5mm @ 140 keV (Tc-99)
- Maximum Sensitivity: ≥ 37 cps/kBq @ 140 keV (Tc-99) (850 cps/μCi)
- Sensitivity at 1 cm: ≥ 3.4 cps/kBq @ 140 keV (Tc-99) (125 cps/μCi)
- Range of Isotope Energies Detected: 25 to 662 keV
- System Ingress Protection (IEC 60529): IP X7
- Tablet Ingress Protection: IP 54
- Voltage: 3.0 VDC single use Li Battery
- Maximum Current: 100 mA
- Maximum Power: 225 mW
- Grade of Protection Against Electrical Discharges: Equipment supplied internally (Applicable part type B)
- Lateral Shielding: 99.9% @ 122 keV (Co-57)
- Max Probe Diameter: 1.6″ 40 mm
Item Numbers
5230-0150 GammaPRO, Standard
Includes: Software and Carry Case
5230-0151 Hi-Sense Probe, high sensitivity
5230-0152 Laparoscopic Probe
5230-0153 Angled Probe